home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 02849rti.txt < prev    next >
Encoding:
Text File  |  1998-06-10  |  17.6 KB  |  432 lines

  1.                          SECTION 02849
  2.  
  3.                              RAMPS
  4. NOTE ** REDD Team Manufacturing, Inc. modular aluminum ramp
  5.         systems.
  6. NOTE **
  7. NOTE ** This section is based on products manufactured by
  8.         REDD Team Manufacturing, Inc., located at the
  9.         following address:
  10. NOTE **     6587 State Road 21 North
  11. NOTE **     P.O. Box 658
  12. NOTE **     Keystone Heights FL 32656
  13. NOTE **     Tel:  (800) 648-3696
  14. NOTE **     Tel:  (352) 473-7246
  15. NOTE **     Fax:  (352) 473-0219
  16. NOTE **
  17. NOTE ** REDD Team Manufacturing, Inc. manufactures the
  18.         following:
  19. NOTE **
  20. NOTE **     Universal Ramp Systems(T):  Modular aluminum
  21.         access ramps
  22. NOTE **     for persons with disabilities as well as the
  23.         general public.
  24. NOTE **
  25. NOTE **     Aluminum Gangways:  For access from ship to
  26.         shore, fixed
  27. NOTE **     docks, floating docks, or cruise vessel
  28.         boarding ramps.
  29. NOTE **
  30. NOTE **     Pedestrian Bridges:  Clear span, aluminum or
  31.         steel
  32. NOTE **     construction.
  33. NOTE **
  34. NOTE ** The following specifications section specifies
  35.         Universal Ramp Systems(TM), which are access ramps
  36.         for persons with disabilities as well as the
  37.         general public.
  38. NOTE **
  39. NOTE ** SECTION 02849 - RAMPS, Copyright 1997, The
  40.         Architect's Catalog, Inc.
  41.  
  42.  
  43. PART 1  GENERAL
  44.  
  45. 1.1 SECTION INCLUDES
  46. NOTE ** Delete items below not required for project.
  47.  
  48.     A.  Modular aluminum ramps.
  49.  
  50. 1.2 REFERENCES
  51.  
  52.     A.  Aluminum Association (AA) - Specifications for Aluminum
  53.         Structures.
  54.  
  55.     B.  ANSI/AWS D1.2 - Structural Welding Code - Aluminum.
  56.  
  57.     C.  ASTM A 555/A 555M - Standard Specification for General
  58.         Requirements for Stainless Steel Wire and Wire Rods.
  59.  
  60.     D.  ASTM B 221 - Standard Specification for Aluminum-Alloy
  61.         Extruded Bars, Rods, Wire, Shapes, and Tubes.
  62.  
  63.     E.  ASTM B 221M - Standard Specification for Aluminum-Alloy
  64.         Extruded Bars, Rods, Wire, Shapes, and Tubes (Metric).
  65.  
  66. 1.3 SYSTEM DESCRIPTION
  67.  
  68.     A.  Design Requirements:
  69.         1.  Design ramp, landing, and railing systems of
  70.             interchangeable modular components for site assembly,
  71.             with concealed connection devices; configurations are
  72.             indicated on drawings.
  73. NOTE ** Ensure that configurations on drawings conform to
  74.         the following:
  75. NOTE **
  76. NOTE **     Ramps:  Maximum slope 1 in 12.
  77. NOTE **     Landings:  Minimum size 5 feet (1.5 m) square
  78.         clear area.
  79. NOTE **
  80. NOTE ** When specifying Universal Ramp Systems, add 4
  81.         inches to clear dimensions.  Example: 5 feet 4
  82.         inches (1.6 m)
  83.         2.  Design ramp, landing, and railing systems to comply
  84.             with requirements of the following:
  85. NOTE ** Delete any of the following sub-paragraphs citing
  86.         authorities not relevant to project.
  87.             a.  Americans with Disabilities Act (ADA).
  88.             b.  Americans with Disabilities Act Accessibility
  89.                 Guidelines (ADAAG); Federal Register.
  90.             c.  Southern Building Code Congress International,
  91.                 Inc. (SBCCI).
  92.             d.  Building Officials & Code Administrators
  93.                 International, Inc. (BOCA).
  94.             e.  Uniform Building Code (UBC); International
  95.                 Conference of Building Officials (ICBO).
  96.             f.  National Fire Protection Association (NFPA) 101 -
  97.                 Life Safety Code.
  98.             g.  State Requirements for Educational Facilities
  99.                 (S.R.E.F.); Florida Schools and Universities.
  100.             h.  California Accessibility Regulations, Book 2,
  101.                 Title 24 - Part 2, State Building Code.
  102.             i.  Council of American Building Officials/American
  103.                 Standards Institute (CABO/ANSI).
  104.             j.  Local authorities having jurisdiction over the
  105.                 project.
  106.             k.  AA reference.
  107.             l.  Performance Requirements specified in this
  108.                 section.
  109.  
  110.     B.  Performance Requirements:
  111.         1.  Ramp and landing sections:  Minimum distributed live
  112.             load capacity of 100 pounds per square foot (488 kg
  113.             per sq m), and support concentrated vertical load of
  114.             300 pounds (136 kg) uniformly distributed over 1
  115.             square foot(0.092 sq m) of area; distributed loads
  116.             and concentrated loads not to be applied
  117.             simultaneously.
  118. NOTE ** Retain the following sub-paragraph if specifying
  119.         handrail system.
  120.         2.  Handrails located 34 inches (864 mm) to 38 inches
  121.             (965 mm) above, and parallel to, walking surface; 1-
  122.             1/2 inches (38 mm) grasping rail:
  123.             a.  Support distributed load of 50 pounds per linear
  124.                 foot (74.3 kg/m), applied in any direction.
  125.             b.  Support concentrated horizontal load of 200
  126.                 pounds (90.6 kg), uniformly distributed over 1
  127.                 square foot (0.092 sq m) of area, applied at any
  128.                 point in system.
  129.             c.  Distributed loads and concentrated loads not to
  130.                 be applied simultaneously.
  131. NOTE ** Retain the following sub-paragraph if specifying
  132.         guardrail system.
  133.         3.  Guardrails located 42 inches (1066 mm) above, and
  134.             parallel to, walking surface:
  135.             a.  Support distributed load of 50 pounds per linear
  136.                 foot (74.3 kg/m), applied horizontally at
  137.                 required guardrail height, and simultaneous
  138.                 distributed load of 100 pounds per linear
  139.                 foot(148.7 kg/m), applied vertically downward at
  140.                 top of guardrail.
  141.             b.  Support concentrated horizontal load of 200
  142.                 pounds(90.6 kg), uniformly distributed over 1
  143.                 square foot (0.092 sq m) of area, applied at any
  144.                 point in system.
  145.             c.  Distributed loads and concentrated loads not to
  146.                 be applied simultaneously.
  147.         4.  Guardrail barrier:
  148.             a.  Prohibit 4-inch (101 mm) sphere from passing
  149.                 through any opening.
  150.             b.  Support concentrated horizontal load of 200
  151.                 pounds(90.6 kg), uniformly distributed over 1
  152.                 square foot (0.092 sq m) of area, applied at any
  153.                 point in system.
  154.  
  155. 1.4 SUBMITTALS
  156.  
  157.     A.  Submit under provisions of Section 01300.
  158.  
  159.     B.  Product Data:  Manufacturer's descriptive literature for
  160.         ramp, landing, and railing systems; identify materials
  161.         and finishes.
  162.  
  163.     C.  Shop Drawings:
  164.         1.  Plans:  Indicate ramp configurations; include
  165.             dimensions.
  166.         2.  Elevations:  Indicate railing configurations; include
  167.             grade, landing, railing and threshold heights.
  168.         3.  Details: Indicate connecting and anchoring details of
  169.             components.
  170.  
  171.     D.  Samples:  Two samples, minimum size 6 square inches
  172.         (0.387 sq m), representing each finish specified.
  173.  
  174.     E.  Quality Assurance Submittals:
  175. NOTE ** Delete any sub-paragraphs specifying design data
  176.         not required for project.
  177.         1.  Design Data:  Shop drawings, catalog cuts, and
  178.             brochures for typical pre-engineered ramp, landing,
  179.             and railing system.
  180.         2.  Manufacturer's Instructions:  Printed installation
  181.             instructions for ramp and railing systems; include
  182.             requirements for storing systems until installation.
  183.  
  184.     F.  Closeout Submittals:
  185.         1.  Operation and Maintenance Data:  Manufacturer's
  186.             instructions for maintenance of ramp system
  187.             components and finishes, and for storing and
  188.             relocating ramp system.
  189.         2.  Warranty Documents:  Issued and executed by
  190.             manufacturer.
  191.  
  192.  
  193. 1.5 DELIVERY, STORAGE, AND HANDLING
  194.  
  195.     A.  Store products of this section in manufacturer's unopened
  196.         packaging until installation.
  197.  
  198.     B.  Maintain storage conditions for products of this section
  199.         in accordance with manufacturer's instructions until
  200.         installation.
  201.  
  202. 1.6 PROJECT/SITE CONDITIONS
  203.  
  204.     A.  Field Measurements:  When construction schedule permits,
  205.         obtain field measurements of actual project conditions;
  206.         using shop drawings prepared by ramp manufacturer, note
  207.         discrepancies on submitted shop drawings.
  208.  
  209. 1.7 SEQUENCING
  210.  
  211.     A.  Do not install ramp systems until construction activities
  212.         which would affect, or be affected, by installation of
  213.         ramp systems is complete; such construction activities
  214.         include, but are not limited to:
  215.         1.  Final grading.
  216.         2.  Paving.
  217.         3.  Sodding/seeding.
  218.         4.  Exterior finishes.
  219.         5.  Doors and windows.
  220.  
  221. 1.8 WARRANTY
  222.  
  223.     A.  Manufacturer's Warranty:  Furnish manufacturer's 3-year
  224.         warranty against defects in products.
  225.  
  226.  
  227. PART 2  PRODUCTS
  228.  
  229. 2.1 MANUFACTURERS
  230.  
  231.     A.  Acceptable Manufacturer:  REDD Team Manufacturing, Inc.;
  232.         6587 State Road 21 North, P.O. Box 658, Keystone Heights
  233.         FL 32656; ASD. Tel. (800) 648-3696 or (352) 473-7246, Fax
  234.         (352) 473-0219.
  235. NOTE ** Delete one of the two following paragraphs;
  236.         coordinate with Division 1 requirements.
  237.  
  238.     B.  Requests for substitution will be considered in
  239.         accordance with provisions of Section 01600.
  240.  
  241.     C.  Substitutions:  Not permitted.
  242.  
  243. 2.2 COMPONENTS
  244.  
  245.     A.  Ramp Sections:
  246.         1.  Framing:  Aluminum extruded shapes conforming to ASTM
  247.             B 221/ASTM B 221M, alloy 6063, T6 temper.
  248.         2.  Walking surface:  1-1/2 inches (38 mm) deep by 6
  249.             inches (152 mm) wide aluminum deck, with triple I-
  250.             beam understructure; self-mating profiles to form
  251.             continuous walking surface, without gaps.
  252.         3.  Curb:  Aluminum extruded shape conforming to ASTM B
  253.             221/ASTM B 221M, alloy 6063, T6 temper; continuous
  254.             along each side of walking surface, minimum 3 inches
  255.             (76 mm) high.
  256. NOTE ** Retain one of the following sub-paragraphs to
  257.         specify walkway width; if specifying a dimensional
  258.         width, 36-inch, 48-inch, and 60-inch widths are
  259.         standard - consult manufacturer if custom width is
  260.         required for project.
  261.         4.  Walkway width:  ____________ inches (__ mm).
  262.         5.  Walkway widths:  Indicated on drawings.
  263.  
  264.     B.  Landings:
  265.         1.  Framing:  Aluminum extruded shapes conforming to ASTM
  266.             B 221/ASTM B 221M, alloy 6063, T6 temper.
  267.         2.  Walking surface:  1-1/2 inches (38 mm) deep by 6
  268.             inches (152 mm) wide aluminum deck, with triple I-
  269.             beam understructure; self-mating profiles to form
  270.             continuous walking surface, without gaps.
  271.         3.  Curb:  Aluminum extruded shape conforming to ASTM B
  272.             221/ASTM B 221M, alloy 6063, T6 temper; continuous
  273.             along each side of walking surface, minimum 3 inches
  274.             (76 mm) high.
  275. NOTE ** Retain one of the following sub-paragraphs to
  276.         specify landing size; if specifying a dimensional
  277.         width, 64 inches by 64 inches is standard - consult
  278.         manufacturer if custom sizes are is required for
  279.         project.
  280.         4.  Landing size:  64 inches by 64 inches (1625 mm by
  281.             1625 mm).
  282.         5.  Landing size:  ____ inches by ____ inches (__ mm by
  283.             __ mm).
  284.         6.  Landing sizes:  Indicated on drawings.
  285.  
  286.     C.  Leg Assemblies:
  287.         1.  Legs:  Aluminum extruded shapes conforming to ASTM B
  288.             221/ASTM B 221M, alloy 6063, T6 temper;
  289.             manufacturer's standard units in incremental lengths
  290.             for project conditions.
  291.         2.  Leveling/support pads:  Aluminum extruded shapes
  292.             conforming to ASTM B 221/ASTM B 221M, alloy 6063, T6
  293.             temper; 6 inches (152 mm) by 10 inches (254 mm) by
  294.             1/4 inch (6.3 mm) flat bar.
  295.         3.  Ramp/landing connectors:  Aluminum extruded shapes
  296.             conforming to ASTM B 221/ASTM B 221M, alloy 6063, T6
  297.             temper; with swivel to adjust legs plumb, and
  298.             provision for leg length adjustment for height and
  299.             slope of grade.
  300. NOTE ** Retain railing types specified in the following
  301.         paragraphs, as required by authorities having
  302.         jurisdiction over the project.
  303.  
  304.     D.  Guardrails located 42 inches (1066 mm) above, and
  305.         parallel to, walking surface:
  306.         1.  Vertical posts and 42-inch high guardrail:  Aluminum
  307.             extruded shapes conforming to ASTM B 221/ASTM B 221M,
  308.             alloy 6063, T6 temper, rectangular tube 1-1/2 inches
  309.             (38 mm) by 2 inches (51 mm) by 1/8 (3 mm) inch wall
  310.             thickness with 1/8 (3 mm) inch radiused edges.
  311.         2.  Handrails:  Aluminum extruded tube conforming to ASTM
  312.             B 221/ASTM B 221M, alloy 6063, T6 temper, 1-1/2
  313.             inches (38 mm) outside diameter; top of handrail
  314.             located 34 inches (863 mm) above, and parallel to,
  315.             walking surface.
  316. NOTE ** Delete the following sub-paragraph if not
  317.         specifying optional lower handrail.
  318.         3.  Grasping rails:  Aluminum extruded tube conforming to
  319.             ASTM B 221/ASTM B 221M, alloy 6063, T6 temper, 1-1/4
  320.             inches (32 mm) outside diameter; top of handrail
  321.             located 26 inches (660 mm) above, and parallel to,
  322.             walking surface.
  323. NOTE ** Delete the following sub-paragraph if not
  324.         specifying optional vertical balusters.
  325.         4.  Vertical barrier balusters:  Aluminum extruded square
  326.             tube conforming to ASTM B 221/ASTM B 221M, alloy
  327.             6063, T6 temper, 3/4 inches (19 mm) square; spaced at
  328.             4 inches (101 mm) on centers.
  329.  
  330.         5.  Guardrail barrier mesh:  2 inch (50 mm) galvanized or
  331.             vinyl coated fencing material.
  332.  
  333.     E.  Horizontal Two-Line Handrails:
  334.         1.  Top grasping rails:  Aluminum extruded tube
  335.             conforming to ASTM B 221/ASTM B 221M, alloy 6063, T6
  336.             temper, 1-1/2 inches (38 mm) outside diameter; top of
  337.             handrail located 38 inches (965 mm) above, and
  338.             parallel to, walking surface.
  339.         2.  Lower rails:  Aluminum extruded tube conforming to
  340.             ASTM B 221/ASTM B 221M, alloy 6063, T6 temper, 1-1/4
  341.             inches (32 mm) outside diameter; top of rail located
  342.             26 inches (660 mm) above, and parallel to, walking
  343.             surface.
  344.  
  345.     F.  Horizontal Two-Line Handrails with Vertical Barrier
  346.         Baluster:
  347.         1.  Top grasping rails:  Aluminum extruded tube
  348.             conforming to ASTM B 221/ASTM B 221M, alloy 6063, T6
  349.             temper, 1-1/2 inches (38 mm) outside diameter; top of
  350.             handrail located 38 inches (965 mm) above, and
  351.             parallel to, walking surface.
  352.         2.  Lower rails:  Aluminum extruded tube conforming to
  353.             ASTM B 221/ASTM B 221M, alloy 6063, T6 temper, 1-1/4
  354.             inches (32 mm) outside diameter; top of rail located
  355.             26 inches (660 mm) above, and parallel to, walking
  356.             surface.
  357.         3.  Vertical barrier balusters:  Aluminum extruded square
  358.             tube conforming to ASTM B 221/ASTM B 221M, alloy
  359.             6063, T6 temper, 3/4 inches (19 mm) square; spaced at
  360.             4 inches (101 mm) on centers.
  361.  
  362.     G.  Fasteners:  Machined from stainless steel conforming to
  363.         ASTM A 555/A 555M, type 18-8, grade 304.
  364.  
  365. 2.3 FABRICATION
  366.  
  367.     A.  Weld aluminum components by gas metal arc-welding (GMAW)
  368.         process in accordance with ANSI/AWS D1.2.
  369.  
  370.     B.  Deburr exposed surfaces to smooth finish, free of sharp
  371.         or jagged edges.
  372.  
  373.     C.  Fabricate railings to form smooth continuous gripping
  374.         surface along ramps and landings.
  375.  
  376. 2.4 FINISHES
  377.  
  378.     A.  Ramp and landing deck walking surfaces:  Extruded slip-
  379.         resistant surface having minimum coefficient of friction
  380.         of 0.5.
  381. NOTE ** Retain one of the following paragraphs to specify
  382.         aluminum finish.
  383.  
  384.     B.  All other sight-exposed surfaces:  Mill finish.
  385.  
  386.     C.  All other sight-exposed surfaces:  Clear satin anodized
  387.         finish conforming to AA M10 C22 A31.
  388.  
  389.     D.  All other sight-exposed surfaces:  Dark bronze anodized
  390.         finish conforming to AA M10 C22 A34.
  391. NOTE ** Delete the preceding paragraphs specifying
  392.         finishes, and retain the following paragraph if
  393.         specifying custom finish; consult manufacturer for
  394.         information required to specify finish correctly.
  395.  
  396.     E.  All other sight-exposed surfaces:  ___________ finish
  397.         conforming to ____________.
  398.  
  399. PART 3  EXECUTION
  400.  
  401. 3.1 EXAMINATION
  402.  
  403.     A.  Verify that grade and threshold elevations are within
  404.         adjustment tolerances of ramp system.
  405.  
  406. 3.2 INSTALLATION
  407.  
  408.     A.  Install ramp system in accordance with shop drawings and
  409.         manufacturer's instructions.
  410.  
  411.     B.  Ensure that ramps are at indicated slopes, that landings
  412.         are level, and that legs are plumb.
  413.  
  414. 3.3 PROTECTION
  415. NOTE ** Delete the following paragraph if allowing
  416.         construction traffic to use ramp systems for
  417.         building access.
  418.  
  419.     A.  Do not allow construction traffic to use installed ramp
  420.         systems.
  421.  
  422.     B.  Protect installed ramp systems from damage by subsequent
  423.         construction activities until Substantial Completion.
  424.  
  425.     C.  Repair damage to finishes or operation of ramp systems
  426.         caused by subsequent construction in accordance with
  427.         manufacturer's recommendations; replace components which
  428.         cannot be repaired to Architect's acceptance.